Small Diesel Fire Pump
Product Details
| Customization: | Available |
|---|---|
| Max.Head: | 80-110m |
| Max.Capacity: | 50-100 L/min |
Shipping
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Payment Guarantee
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Manufacturer/Factory & Trading Company
360° Virtual Tour
Secured Trading Service
Diamond Member Since 2025
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
Self-branded
Patents Awarded
Raw-Materials Traceability
The supplier has import and export rights
The supplier has 3 Self-brands, check the Audit Report for more information
The supplier had awarded 1 patents, you can check the Audit Report for more information
The supplier has traceability identification of raw materials
Sign In to see all verified strength labels (13)
Find Similar Products
Basic Info.
- Model NO.
- XBC6.0/15G-MW
- Driving Type
- Diesel Oil
- Material
- Cast Iron
- Structure
- Single-stage Pump
- Assembly
- Pipeline Pump
- Power
- Diesel Oil
- Start Up
- Diesel Oil
- Type
- Jet Pump
- Application
- Water Supply or Delivery in Fire Protection System
- Industry
- Mechanical Pump
- Media
- Clear Water
- Performance
- Wear Pump
- Theory
- Jet Pump
- Transport Package
- Wooden Case Packaging
- Origin
- Wenzhou, Zhejiang, China
- Production Capacity
- 10000
Packaging & Delivery
- Package Size
- 700.00cm * 520.00cm * 650.00cm
- Package Gross Weight
- 110.000kg
- Lead Time
-
25 days (1 - 10 Sets)
To be negotiated ( > 10 Sets)
Product Description
Introduction to Diesel Engine Fire Pump
A diesel engine fire pump is a specialized pump unit designed for emergency fire-fighting water supply, with a diesel engine as its power source. Its core advantage lies in not requiring external electricity, enabling it to start quickly in emergency situations such as power outages to ensure uninterrupted fire-fighting water supply.
A diesel engine fire pump is a specialized pump unit designed for emergency fire-fighting water supply, with a diesel engine as its power source. Its core advantage lies in not requiring external electricity, enabling it to start quickly in emergency situations such as power outages to ensure uninterrupted fire-fighting water supply.


Detailed Introduction
Structural Composition
A diesel engine fire pump unit is mainly composed of three core parts and auxiliary systems:
- Power System: The core is a diesel engine (usually a high-speed, high-power diesel engine), equipped with a dedicated starting battery, air filter, fuel filter, oil filter, etc., to provide continuous power for the pump unit.
Structural Composition
A diesel engine fire pump unit is mainly composed of three core parts and auxiliary systems:
- Power System: The core is a diesel engine (usually a high-speed, high-power diesel engine), equipped with a dedicated starting battery, air filter, fuel filter, oil filter, etc., to provide continuous power for the pump unit.
- Pump Body System: Mostly adopts a single-suction single-stage or multi-stage centrifugal pump structure, including components such as pump body, impeller, pump shaft, and mechanical seal. It is responsible for converting mechanical energy into liquid pressure energy to achieve water absorption and pressurized water supply.
- Control System: Equipped with a dedicated automatic control cabinet, which integrates functions such as automatic start, speed monitoring, oil pressure, water temperature, oil temperature monitoring, fault alarm (e.g., low oil pressure, high water temperature), and emergency shutdown. Some high-end models support remote monitoring.
- Auxiliary Components: Also include a fuel tank, cooling system (water tank or air-cooled device), shock absorption device, coupling (connecting the diesel engine and pump shaft), and a common base (facilitating installation and fixation).



right elevation
left elevation
front elevation


Working Principle
1. Start-up Phase: When the fire protection system detects a fire (e.g., pressure drop, fire signal trigger) or a power outage, the control system starts the diesel engine automatically (or manually).
1. Start-up Phase: When the fire protection system detects a fire (e.g., pressure drop, fire signal trigger) or a power outage, the control system starts the diesel engine automatically (or manually).
2. Power Transmission: After the diesel engine starts, it drives the pump shaft and impeller to rotate at high speed through the coupling.
3. Water Suction and Pressurization: The rotating impeller generates centrifugal force, which draws the liquid in the pump body into it. Under the action of the impeller, the liquid is accelerated and pressurized to increase its energy.
4. Water Supply Output: The pressurized liquid is delivered to systems such as fire hydrants and automatic sprinklers through the outlet pipeline of the pump unit to meet fire-fighting needs. Meanwhile, the control system monitors the operating status of the unit in real time to ensure stable water supply.
Performance Parameters
- Flow Rate Range: Generally 10L/s - 300L/s, and models with larger flow rates can be customized according to fire-fighting requirements.
- Flow Rate Range: Generally 10L/s - 300L/s, and models with larger flow rates can be customized according to fire-fighting requirements.
- Head Range: Typically 50m - 250m. The multi-stage pump structure can achieve a higher head to meet the water supply needs of high-rise buildings or long-distance water supply.
- Rated Pressure: The common range is 0.5MPa - 2.5MPa, and some high-pressure models can reach higher pressures.
- Start-up Time: The emergency start-up time is ≤ 30 seconds (complying with fire protection code requirements), enabling quick response to fire situations.
- Continuous Operation Time: The full-load continuous operation time is generally ≥ 8 hours (depending on the fuel tank capacity, which can be extended by an external fuel tank).
- Medium Requirements: It mainly transports clean water or fire-fighting water with a small amount of impurities, and the medium temperature is usually -10℃ - 80℃.
FAQ
Q: What's the lead time for orders?
A: Standard models ship in 15–30 days; customized units require 30–45 days.
A: Standard models ship in 15–30 days; customized units require 30–45 days.
Q: Can I request a customized bucket size?
A: Absolutely! We offer tailored attachments.
A: Absolutely! We offer tailored attachments.
Q: What documents do you provide for export?
A: Full export package (Commercial Invoice, Packing List, Bill of Lading, COC, etc.).
A: Full export package (Commercial Invoice, Packing List, Bill of Lading, COC, etc.).
Q: How do I place an order?
A: Contact us via email/phone for a quote, then confirm with a PO.
A: Contact us via email/phone for a quote, then confirm with a PO.
Send your message to this supplier
People who viewed this also viewed
Find Similar Products By Category
- Supplier Homepage
- Products
- fire pump
- Small Diesel Fire Pump
Related Categories
Hot Searches
More